Micsig RCP120000-XS Rogowski current probe
€949.00 Net
€1,129.31 incl. VAT
Delivery time: 2 weeks
Delivery time: 2 weeks
Features
- Coil diameter: 1.6mm
- Coil length: 80mm
- Current range 12000A
- 30 MHz bandwidth
Description
Product description
RCP series Rogowski current probes (AC)
The RCP series Rogowski current probes are high-precision, flexible current probes for contactless measurement of alternating currents in power electronics, development, production and quality assurance.
They enable the reliable acquisition of highly dynamic current curves up to 12,000 Apk at a bandwidth of up to 30 MHz without significantly influencing the measuring circuit.
Thanks to the almost zero ohm insertion resistance , the probes are ideal for applications in which conventional current clamps or shunts would distort the measurement result. The flexible Rogowski coil also allows measurements in hard-to-reach places, on individual pins or in cramped assemblies.
All probes have a standardised BNC output (1 MΩ) and are therefore compatible with almost all oscilloscopes.
Series overview & areas of application
RCP-XS series - ultra-compact measurements
The RCP-XS series is characterised by an extremely small coil cross-section of just 1.6 mm .
It has been specially developed for pin-level measurements on semiconductors such as MOSFETs and IGBTs (TO-220, TO-247 etc.).
Typical applications:
Measurement of drain and source currents on MOSFETs
Double-pulse tests (SiC / GaN)
High-frequency switching current analysis
Measurements in very narrow assemblies
RCP-S Series - Universal power electronics
The RCP-S series is the all-rounder for development and diagnostic tasks in power electronics.
It combines high bandwidth with robust coil geometry and higher insulation voltage.
Typical applications:
Switch-mode power supplies (SMPS)
Converters, inverters, UPS
Current measurements in 3-phase systems
Analysing load and harmonic currents
RCP-M series - Increased dielectric strength
The RCP-M series offers a higher insulation voltage with high bandwidth.
It is ideal for industrial applications with increased voltage requirements.
Typical applications:
Power modules and industrial converters
Development and validation measurements
Measurements on power electronics with higher insulation requirements
RCP-L series - high current & high voltage
The RCP-L series is designed for large conductor diameters, high voltages and harsh industrial environments .
With insulation voltages of up to 10 kVpk , it is particularly suitable for energy and grid applications.
Typical applications:
Motor drives
Energy and grid analyses
High-current measurements in industrial plants
Measurement of 50/60 Hz mains currents
Application notes
The cable to be measured should be positioned as centrally as possible in the coil in order to achieve maximum accuracy.
Strong external magnetic fields should be avoided to reduce measurement errors.
The Rogowski coil can also be used to detect interference or stray fields .
Before measuring, ensure that:
the oscilloscope is set to 1 MΩ input resistance
the probe is properly supplied with voltage
the coil is correctly closed
Features
Further functions

Measure the ID current of the MOSFET
The RCP series probes have excellent high-frequency measurement capabilities, easily handle high-speed signals and rapidly changing current waveforms, and help observe high-frequency harmonic components when measuring the ID current of MOSFETs.

BNC interface
The RCP Rogowski series has a standard BNC interface making it compatible with any oscilloscope from any manufacturer.

Different coil cross-sections
The cross-sectional diameter of the smallest coil is only 1.6 mm, allowing engineers to measure the current on the hard-to-reach parts of the circuit, for example on chips with narrow pin spacing such as TO-220, TO-47.

Applications
- Measurement of current with a mains frequency of 50/60 Hz
- Measurement of harmonic components in the current
- Measurement of pin currents in MOSFET or IGBT devices
- Measurement of load currents and higher-order harmonic currents in power electronics
- Measurement of current in motor drives and for power quality (VSD, UPS, SMPS)
- Double-pulse tests for pin currents in SiC and GaN semiconductors
Specifications
| Parameters | RCP-XS Series | RCP-S Series | RCP-M Series | RCP-L series |
|---|---|---|---|---|
| Typical coil cross-section | 1.6 mm | 3.0 mm | 4.5 mm | 8.0 mm |
| Available spool circumferences | 80 mm, 200 mm | 200 mm, 700 mm | 200 mm, 700 mm | 700 mm |
| Measurable conductor diameter | ≤ 20 mm / ≤ 60 mm | ≤ 60 mm / ≤ 220 mm | ≤ 60 mm / ≤ 220 mm | ≤ 220 mm |
| Max. Bandwidth | 30 MHz | 25 MHz | 25 MHz | 10 MHz |
| Measuring range (peak current) | 60 Apk - 12,000 Apk | 120 Apk - 12,000 Apk | 120 Apk - 12,000 Apk | 600 Apk - 12,000 Apk |
| Typical accuracy | 2 % | 2 % | 2 % | 2 % |
| Max. Coil insulation voltage | 1.5 kVpk | 3 kVpk | 5 kVpk | 10 kVpk |
| Typical applications | Pin-level measurements, MOSFET / IGBT, SiC / GaN, very tight installation spaces | Power electronics, SMPS, inverters, Development & diagnostics | Industrial applications, higher voltages, robust measurements | High current & high voltage, Motors, energy, Grid & industrial applications |
RCP-L series (typical coil cross-section diameter: 8.0 mm)
| Model | Bandwidth | Peak current | Output sensitivity | Output noise | Max. di/dt | Droop (%/ms) | Output accuracy | Max. Coil insulation voltage | Coil circumference |
|---|---|---|---|---|---|---|---|---|---|
| RCP600L-700 | 8 Hz - 10 MHz | 600 Apk | 10 mV/A (100×) | <18 mVpp | 70 kA/µs | 8 | 2 % | 10 kVpk | 700 mm |
| RCP1200L-700 | 6 Hz - 10 MHz | 1200 Apk | 5 mV/A (200×) | <12 mVpp | 70 kA/µs | 5 | 2 % | 10 kVpk | 700 mm |
| RCP3000L-700 | 4 Hz - 10 MHz | 3000 Apk | 2 mV/A (500×) | <9 mVpp | 70 kA/µs | 2 | 2 % | 10 kVpk | 700 mm |
| RCP6000L-700 | 3 Hz - 10 MHz | 6000 Apk | 1 mV/A (1000×) | <6 mVpp | 70 kA/µs | 2 | 2 % | 10 kVpk | 700 mm |
| RCP12000L-700 | 2 Hz - 10 MHz | 12000 Apk | 0.5 mV/A (2000×) | <5 mVpp | 70 kA/µs | 2 | 2 % | 10 kVpk | 700 mm |
RCP-M series (typical coil cross-section diameter: 4.5 mm)
| Model | Bandwidth | Peak current | Output sensitivity | Output noise | Max. di/dt | Droop (%/ms) | Output accuracy | Max. Coil insulation voltage | Coil circumference |
|---|---|---|---|---|---|---|---|---|---|
| RCP120M-200 | 14 Hz - 25 MHz | 120 Apk | 50 mV/A (20×) | <25 mVpp | 8 kA/µs | 18 | 2 % | 5 kVpk | 200 mm |
| RCP300M-200 | 7 Hz - 25 MHz | 300 Apk | 20 mV/A (50×) | <20 mVpp | 20 kA/µs | 8 | 2 % | 5 kVpk | 200 mm |
| RCP600M-200 | 5 Hz - 25 MHz | 600 Apk | 10 mV/A (100×) | <18 mVpp | 40 kA/µs | 5 | 2 % | 5 kVpk | 200 mm |
| RCP1200M-200 | 5 Hz - 25 MHz | 1200 Apk | 5 mV/A (200×) | <7 mVpp | 70 kA/µs | 5 | 2 % | 5 kVpk | 200 mm |
| RCP3000M-200 | 3 Hz - 25 MHz | 3000 Apk | 2 mV/A (500×) | <7 mVpp | 70 kA/µs | 2 | 2 % | 5 kVpk | 200 mm |
| RCP6000M-200 | 2 Hz - 25 MHz | 6000 Apk | 1 mV/A (1000×) | <5 mVpp | 70 kA/µs | 2 | 2 % | 5 kVpk | 200 mm |
| RCP6000M-700 | 3 Hz - 10 MHz | 6000 Apk | 1 mV/A (1000×) | <6 mVpp | 70 kA/µs | 3 | 2 % | 5 kVpk | 700 mm |
| RCP12000M-700 | 2 Hz - 10 MHz | 12000 Apk | 0.5 mV/A (2000×) | <5 mVpp | 70 kA/µs | 2 | 2 % | 5 kVpk | 700 mm |
RCP-S series (typical coil cross-section diameter: 3.0 mm)
| Model | Strip width | Peak current | Output sensitivity | Output noise | Max. di/dt | Droop (%/ms) | Output accuracy | Max. Coil insulation voltage | Coil circumference |
|---|---|---|---|---|---|---|---|---|---|
| RCP120S-200 | 14 Hz - 25 MHz | 120 Apk | 50 mV/A (20×) | <25 mVpp | 8 kA/µs | 18 | 2 % | 3 kVpk | 200 mm |
| RCP300S-200 | 7 Hz - 25 MHz | 300 Apk | 20 mV/A (50×) | <20 mVpp | 20 kA/µs | 8 | 2 % | 3 kVpk | 200 mm |
| RCP600S-200 | 5 Hz - 25 MHz | 600 Apk | 10 mV/A (100×) | <18 mVpp | 40 kA/µs | 5 | 2 % | 3 kVpk | 200 mm |
| RCP1200S-200 | 5 Hz - 25 MHz | 1200 Apk | 5 mV/A (200×) | <7 mVpp | 70 kA/µs | 5 | 2 % | 3 kVpk | 200 mm |
| RCP3000S-200 | 3 Hz - 25 MHz | 3000 Apk | 2 mV/A (500×) | <7 mVpp | 70 kA/µs | 2 | 2 % | 3 kVpk | 200 mm |
| RCP6000S-200 | 2 Hz - 25 MHz | 6000 Apk | 1 mV/A (1000×) | <5 mVpp | 70 kA/µs | 2 | 2 % | 3 kVpk | 200 mm |
| RCP6000S-700 | 3 Hz - 10 MHz | 6000 Apk | 1 mV/A (1000×) | <6 mVpp | 70 kA/µs | 3 | 2 % | 3 kVpk | 700 mm |
| RCP12000S-700 | 2 Hz - 10 MHz | 12000 Apk | 0.5 mV/A (2000×) | <5 mVpp | 70 kA/µs | 2 | 2 % | 3 kVpk | 700 mm |
RCP-XS series (typical coil cross-section diameter: 1.6 mm)
| Model | Bandwidth | Peak current | Output sensitivity | Output noise | Max. di/dt | Droop (%/ms) | Output accuracy | Max. Coil insulation voltage | Coil circumference |
|---|---|---|---|---|---|---|---|---|---|
| RCP60XS-80 | 70 Hz - 30 MHz | 60 Apk | 100 mV/A (10×) | <25 mVpp | 4 kA/µs | 65 | 2 % | 1.5 kVpk | 80 mm |
| RCP120XS-80 | 34 Hz - 30 MHz | 120 Apk | 50 mV/A (20×) | <25 mVpp | 8 kA/µs | 35 | 2 % | 1.5 kVpk | 80 mm |
| RCP300XS-80 | 10 Hz - 30 MHz | 300 Apk | 20 mV/A (50×) | <25 mVpp | 20 kA/µs | 9 | 2 % | 1.5 kVpk | 80 mm |
| RCP600XS-80 | 8 Hz - 30 MHz | 600 Apk | 10 mV/A (100×) | <18 mVpp | 40 kA/µs | 7 | 2 % | 1.5 kVpk | 80 mm |
| RCP1200XS-80 | 5 Hz - 30 MHz | 1200 Apk | 5 mV/A (200×) | <15 mVpp | 70 kA/µs | 3 | 2 % | 1.5 kVpk | 80 mm |
| RCP3000XS-80 | 4 Hz - 30 MHz | 3000 Apk | 2 mV/A (500×) | <8 mVpp | 70 kA/µs | 2 | 2 % | 1.5 kVpk | 80 mm |
| RCP6000XS-80 | 4 Hz - 30 MHz | 6000 Apk | 1 mV/A (1000×) | <5 mVpp | 70 kA/µs | 2 | 2 % | 1.5 kVpk | 80 mm |
| RCP12000XS-80 | 2 Hz - 30 MHz | 12000 Apk | 0.5 mV/A (2000×) | <6 mVpp | 70 kA/µs | 2 | 2 % | 1.5 kVpk | 80 mm |
| RCP300XS-200 | 14 Hz - 20 MHz | 300 Apk | 20 mV/A (50×) | <20 mVpp | 20 kA/µs | 15 | 2 % | 1.5 kVpk | 200 mm |
| RCP600XS-200 | 7 Hz - 20 MHz | 600 Apk | 10 mV/A (100×) | <18 mVpp | 40 kA/µs | 7 | 2 % | 1.5 kVpk | 200 mm |
| RCP1200XS-200 | 5 Hz - 20 MHz | 1200 Apk | 5 mV/A (200×) | <15 mVpp | 70 kA/µs | 3 | 2 % | 1.5 kVpk | 200 mm |
| RCP6000XS-200 | 3 Hz - 20 MHz | 6000 Apk | 1 mV/A (1000×) | <7 mVpp | 70 kA/µs | 3 | 2 % | 1.5 kVpk | 200 mm |