RCP500-Serie

RCP 500 Rigowski series

The RCP500 series enables the non-invasive measurement of current-carrying conductors and offers a wide measuring range of up to 500 A.
  • Bandwidth: 15-300 kHz (-3 dB).
  • Current range: 200mApk-500Apk
  • Output sensitivity: 10 mV/A
  • Typical accuracy: 1 %

RCP500 Rigowski series


The Micsig RCP500 is a flexible Rogowski current clamp that has been specially developed for the precise measurement of alternating currents. It offers a bandwidth of 15 Hz to 300 kHz and can measure currents in the range of 200 mA to 500 A peak with a typical accuracy of 1 %. This high accuracy remains constant over the entire measurement range as the system is based on a linear output signal that remains proportional to the measured current.

An outstanding feature of the RCP500 is its ability to measure complex current signals, including transient inrush currents of power electronics components, sinusoidal currents in three-phase power supply systems and current measurements of IGBTs and MOSFETs. The probe is able to minimise the phase shift between the output signal and the current waveform to less than 0.8°, which enables very precise signal reproduction.

The RCP500 has a robust and compact design, including a thin Rogowski coil with an inner diameter of 50 mm, which makes it possible to perform measurements even in confined environments. The probe is compatible with the Micsig UPI multifunction probe interface, which means it can be used directly with the latest Micsig oscilloscopes without the need for an additional power supply. Alternatively, it can be connected to oscilloscopes from other manufacturers using a Micsig PA05 adapter.

Further advantages of the RCP500 include its low noise generation of less than 2 mV rms and its high immunity to external magnetic fields, which have an influence of less than 1.5 % on the measurement result. The maximum operating voltage is 10 kV RMS (only for the Rogowski coil part), which makes the probe suitable for high voltage applications.

Overall, the Micsig RCP500 is a versatile and precise current clamp that is ideal for demanding measurement tasks in power electronics and other areas where accurate measurement of alternating currents is required.

More detailed information on the functions can be found on the respective product model page
rcp500-unboxing

Series overview

Model specificationRCP500-Serie-min-small
RCP500
Bandwidth15 Hz - 300 KHz
Measuring range200 mA - 500 A
Output connectionPowered BNC / External BNC
Output sensitivity10 mV/A
Output accuracy1%
Phase accuracy≤0.8° (45Hz-66Hz)    
Temperature coefficientOperating temperature. Range + 0.05 × accuracy specification /℃ (23℃±5℃)
Position accuracy of the conductorWithin ±1% (deviation from the centre)
Influence of external magnetic fields1.5 % fs or less (400 A/m, 50 Hz/60 Hz)
Offset voltage±1mV or less  
Maximum voltageAC 10 kV RMS (1 minute), (50 Hz/60 Hz) (only part of Rogowski coil)
Output impedanceHigh resistance 
Output noise<2mv rms   
Diameter of the conductor to be tested≤Φ50mm    
Power supplyDirect current 5V  
Cable length from coil to integrator2m (customisable)
Integrator dimensions37*22*82mm   
Inner diameter of Rogowski coil50 mm (customisable) 
Thickness of the Rogowski coilApprox. Ø6mm  
Operating temperature-20℃ - 70℃   
Storage temperature-30℃ - 70℃   

All models

Micsig-RCP500-StromsondeMicsig RCP500 Koffer
RCP500
RCP500 Rogowski current probe
The Micsig RCP500 current probe provides measurements at AC currents from 200mA to 500A at 15 Hz to 300 KHz.

€176.00*