Micsig RCP3000-XS Rogowski current probe

Model: RCP3000XS
The Micsig RCP3000-XS Rogowski current probe has a measuring range of 3000 Apk and a bandwidth of 30 MHz.

€999.00*

Content: 1
Volume discounts on request!

In Stock, Delivery time: 1 - 3 days

Model
Request a quote
Further information
Product number: RCP3000XS

Features

  • Measuring range 3000Apk
  • bandwidth 30 MHz
  • accuracy 2%

Description

The Micsig RCP3000-XS Rigowski current probe offers a measurement range of 3000Apk with a bandwidth of up to 30 MHz.

The Micsig RCP series offers an advanced solution for the precise detection of alternating currents in demanding technical applications. With an impressive bandwidth of up to 30 MHz and the ability to measure peak currents of up to 6000 amps, the RCP series is ideally suited for analysing high-frequency and power-intensive signals in modern power electronics systems, motor controls and high-voltage applications.

A particularly notable feature of the RCP series is the ultra-thin, flexible Rogowski coil with a cross-sectional diameter of just 1.6 mm. This extremely compact design makes it possible to carry out measurements even in areas that are difficult to access, such as the connection legs of TO-220 and TO-247 MOSFETs. The high measurement accuracy of typically 2 % and the virtually non-existent insertion impedance minimise system-related interference while guaranteeing accurate results.

The RCP series is equipped with a universal BNC interface that enables seamless connection to virtually any oscilloscope, which simplifies integration into existing measurement systems and underlines the flexibility of the series. The series also offers excellent noise rejection, making it particularly suitable for use in environments with high levels of electromagnetic noise.

With the ability to accurately measure both small and large alternating currents - including high-frequency sinusoidal, pulsed or transient currents - the RCP series is extremely versatile. It is ideal for applications such as load current measurement, high frequency circuit monitoring, double pulse testing and power monitoring in semiconductor components.

Overall, the Micsig RCP series offers an optimal combination of flexibility, high precision and ease of use. Its compact and sophisticated design, together with the ability to perform accurate measurements in complex environments, makes it an indispensable tool for engineers and technicians working in power electronics and other demanding fields.
Overview RCP Series

Features

Further functions

Specifications

ModelMicsig-RCP-Series-small
RCP60-XS
Micsig-RCP-Series-small
RCP120-XS
Micsig-RCP-Series-small
RCP300-XS
Micsig-RCP-Series-small
RCP600-XS
Micsig-RCP-Series-small
RCP1200-XS
Micsig-RCP-Series-small
RCP3000-XS
Micsig-RCP-Series-small
RCP6000-XS
Micsig-RCP-Series-small
RCP12000-XS
Bandwidth85 Hz - 30 MHz34 Hz - 30 MHz10 Hz - 30 MHz10 Hz - 30 MHz12 Hz - 30 MHz3 Hz - 30 MHz2 Hz - 30 MHz2 Hz - 30 MHz
Measuring range60Apk120Apk300Apk600Apk1200Apk3000Apk6000Apk12000Apk
Output sensitivity100 mV/A (10x)50 mV/A (20x)20 mV/A (50x)10 mV/A (100x)5 mV/A (200x)2 mV/A (500x)1 mV/A (1000x)0.5 mV/A (2000x)
Accuracy (typical)2 %2 %2 %2 %2 %2 %2 %2%
Droop65%/ms35%/ms 9%/ms6%/ms3%/ms2%/ms2%/ms2%/ms
Noise<20 mVpp <20mVpp<18 mVpp<12 mVpp<5 mVpp<5 mVpp<5 mVpp<6 mVpp
Peak voltage of the coil insulationAC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil part only )AC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil section only )AC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil section only )AC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil section only )AC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil section only )AC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil section only )AC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil section only )AC 1 kVrms (1 min.) (50 Hz/60 Hz) ( Rogowski coil section only )
Cable length1.5m
(customisable to order)
1.5m
(customisable to order)
1.5m
(customisable to order)
1.5m
(Customisable to order)
1,5m
(Customisable to order)
1,5m
(Customisable to order)
1,5m
(Customisable to order)
1.5m
(Customisable to order)
Inner diameter of the Rogowski coil25 mm
measures cables with a diameter of up to 20 mm
(customisable to order)
25 mm
measures cables with a diameter of up to 20 mm
(customisable to order)
25 mm
measures cables with a diameter of up to 20 mm
(customisable, can be ordered)
25 mm
measures cables with a diameter of up to 20 mm
(customisable, can be ordered)
25 mm
measures cables with a diameter of up to 20 mm
(customisable, can be ordered)
25 mm
measures cables with a diameter of up to 20 mm
(customisable, can be ordered)
25 mm
measures cables with a diameter of up to 20 mm
(customisable, can be ordered)
25 mm
measures cables with a diameter of up to 20 mm
(customisable to order)
Circumference of the Rogowski coils80 mm, customisable80 mm, customisable80 mm, customisable80 mm, customisable80 mm, customisable80 mm, adjustable80 mm, adjustable80 mm, customisable
Coil cross-section diameter1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm1.6 mm
Interface1MΩ BNC1MΩ BNC1MΩ BNC1MΩ BNC1MΩ BNC1MΩ BNC1MΩ BNC1MΩ BNC